  rg-174/u type ?26 awg stranded (7x34) .019 bare copper-covered steel conductor ?tinned copper braid shield (90% coverage) polyethylene insulation ?black pvc jacket ul awm 8216 100 30.5 1.1 .5 26 awg .060 1.52 tc braid .110 2.79 50 66% 30.8 101.0 style 1354 500 152.4 5.0 2.3 (7x34) 90% shield (30v 75?) 1000 ?? 304.8 9.0 4.1 .019 coverage bccs 10.7 ? /m 97.0 ? /m 35.1 ? /km 318.2 ? /km rg-188a/u type ?26 awg stranded (7x34) .020 silver-plated copper-covered steel conductor ?spc braid shield (96% coverage) tfe teflon insulation ?white tfe tape jacket 200? 83269 100 ? 30.5 2.0 .9 26 awg .058 1.47 spc braid .098 2.49 50 69.5% 29.0 95.1 vw-1 500 ? 152.4 6.5 2.9 (7x34) 96% shield 1000 ? 304.8 12.0 5.5 .020 coverage scccs 8.5 ? /m 91.2 ? /m 27.9 ? /km 299.2 ? /km mil-c-17d rg-58/u type ?20 awg solid .033 bare copper conductor ?bare copper braid shield (78% coverage) polyethylene insulation ?black pvc jacket 80? 9201 u-500 u-152.4 13.0 5.9 20 awg .116 2.95 bc braid .193 4.90 51.5 66% 28.5 93.5 500 152.4 11.5 5.2 (solid) 78% shield u-1000 u-304.8 25.0 11.4 .033 coverage 1000 304.8 23.0 10.4 bc 5.5 ? /m 10.0 ? /m 18.0 ? /km 33.1 ? /km rg-58/u type ?20 awg solid .033 bare copper conductor ?duobond ii + tinned copper braid shield (55% coverage) polyethylene insulation ?black pvc jacket ul awm 9310 ** 500 152.4 10.5 4.8 20 awg .114 2.90 duobond ii* .193 4.90 50 66% 30.8 101.0 style 1354 u-1000 u-304.8 22.0 10.0 (solid) + 55% (30v 60?) 1000 304.8 21.0 9.5 .033 tc braid bc 8.0 ? /m 9.4 ? /m 24.4 ? /km 28.6 ? /km bc = bare copper bccs = bare copper-covered steel dcr = dc resistance scccs = silver-coated copper-covered steel spc = silver-p lated copper tc = tinned copper tfe = tetra fluoroethylene contact the belden customer service department for a comprehensive connector cross reference. 1-800-belden-1 . request quotations of rg/u cables not listed. *duobond ii = bonded duofoil (100% coverage) + aluminum braid (67% coverage). **see beldens website, www.belden.com, for connector information. ? may contain more than one piece, min. length of any one piece is 25 ft. ?? may contain more than one piece, min. length of any one piece is 100 ft. length may vary ?0% from length shown. coaxial cables 6.67 6 coaxial cables for more information, contact belden technical support: 1-800-belden-1 ?www.belden.com 50 ohm transmission and computer cable rg-188a/u, rg-174/u and rg-58/u type 1 1.9 6.2 10 3.3 10.8 50 5.8 19.0 100 8.4 27.6 200 12.5 41.0 400 19.0 62.3 700 27.0 88.6 900 31.0 101.7 1000 34.0 111.5 1 1.2 3.9 10 2.7 8.9 50 5.6 18.4 100 8.3 27.2 200 12.0 39.4 400 17.5 57.4 700 23.7 77.8 900 27.3 89.6 1000 29.0 95.1 teflon is a dupont trademark. 1 .3 1.1 10 1.1 3.6 50 2.5 8.2 100 3.8 12.5 200 5.6 18.4 400 8.4 27.6 700 11.7 38.4 900 13.7 44.9 1000 14.5 47.6 1 .5 1.5 10 1.4 4.6 50 2.8 9.2 100 3.8 12.5 200 5.4 17.7 400 7.9 25.9 700 11.1 36.4 900 12.8 42.0 1000 13.9 45.6 shielding materials nom. dcr nom. imp. ( ? ) nominal core od nominal od inch mm inch mm conductor (stranding) diameter nom. dcr standard unit weight standard lengths lbs. kg ft. m ul nec/ c(ul) cec type part no. mhz db/ 100 ft. db/ 100m nominal attenuation nominal capacitance pf/m pf/ft. nom. vel. of prop. description
coaxial cables 6.68 for more information, contact belden technical support: 1-800-belden-1 ?www.belden.com rg-58a/u type ?20 awg stranded (19x32) .037 tinned copper conductor ?tinned copper braid shield (96% coverage) foam polyethylene insulation ?black or white pvc jacket ul awm 8219 nec: u-500 u-152.4 13.5 6.1 20 awg .114 2.90 tc braid .194 4.93 53.5 73% 26.5 86.9 style 1354 cm 500 152.4 13.0 6.0 (19x32) 96% shield (30v 80?) cec: u-1000 u-304.8 27.0 12.3 .037 coverage cm 1000 304.8 26.0 11.8 tc 4.1 ? /m 8.8 ? /m 13.4 ? /km 28.9 ? /km p-msha sc-182/5** 500 ft. and u-1000 ft. put-ups available in black only. black jacket suitable for aerial (when supported by a messenger) and ou tdoor applications. rg-58a/u type ?20 awg stranded (19x32) .037 tinned copper conductor ?duobond ii* + tinned copper braid shield (55% coverage) foam polyethylene insulation ?black pvc jacket ul awm 9311 ** nec: 500 152.4 10.5 4.8 20 awg .114 2.90 duobond ii* .193 4.90 52 75% 26.0 85.3 style 1354 cm u-1000 u-304.8 23.0 10.5 (19x32) + 55% tc (30v 80?) cec: 1000 304.8 21.0 9.5 .037 braid cm tc 17.0 ? /m 8.8 ? /m 55.8 ? /km 28.9 ? /km rg-58a/u type ?20 awg stranded (19x33) .035 tinned copper conductor ?tinned copper braid shield (95% coverage) polyethylene insulation ?black pvc jacket 75? 8259 100 30.5 3.5 1.6 20 awg .116 2.95 tc braid .192 4.88 50 66% 30.8 101.0 u-500 u-152.4 13.5 6.1 (19x33) 95% shield 500 152.4 13.5 6.1 .035 coverage u-1000 u-304.8 25.0 11.3 tc 4.1 ? /m 1000 304.8 26.0 11.8 10.8 ? /m 13.4 ? /km 35.4 ? /km suitable for aerial (when supported by a messenger) and outdoor applications. rg-58a/u type ?20 awg solid bare copper conductor ?tinned copper braid shield (95% coverage) polyethylene insulation ?black pvc jacket ul awm 8240 nec: 100 30.5 3.6 1.6 20 awg .116 2.95 tc braid .193 4.90 51.5 66% 28.5 93.5 style 1354 cmx u-500 u-152.4 14.0 6.4 (solid) 95% shield (30v 80?) cec: 500 152.4 13.0 5.9 .033 coverage vw-1 cmx u-1000 u-304.8 27.0 12.3 bc 4.1 ? /m 1000 304.8 26.0 11.8 10.0 ? /m 13.4 ? /km 32.8 ? /km suitable for aerial (when supported by a messenger) and outdoor applications. plenum ?fep teflon ? insulation ?black fep teflon jacket 200? 88240 nec: 500 ? 152.4 12.0 5.4 20 awg .107 2.72 tc braid .159 4.04 53.5 69.5% 26.4 86.6 cmp 1000 ? 304.8 24.0 10.9 (solid) 95% shield cec: .032 coverage cmp ft6 bc 6.7 ? /m 10.2 ? /m 22.0 ? /km 33.5 ? /km plenum ?fep teflon insulation ?natural flamarrest jacket 75? 82240 nec: u-500 ? u-152.4 13.5 6.1 20 awg .107 2.72 tc braid .159 4.04 53.5 69.5% 26.4 86.6 cmp u-1000 ? u-304.8 26.0 11.8 (solid) 95% shield cec: 1000 ? 304.8 24.0 10.9 .032 coverage cmp ft6 bc 6.7 ? /m 10.2 ? /m 22.0 ? /km 33.5 ? /km bc = bare copper dcr = dc resistance fep = fluorinated ethylene propylene tc = tinned copper *duobond ii = bonded duofoil?(100% coverage) + aluminum braid (67% coverage). **pennsylvania department of environmental resource and united states mine safety and health administration certification. ? spools and/or unreel cartons are one piece, but length may vary ?0% from length shown. 50 ohm transmission and computer cable rg-58a/u type 1 .3 1.1 10 1.1 3.6 50 2.5 8.2 100 3.8 12.5 200 5.6 18.4 400 8.4 27.6 700 11.7 38.4 900 13.7 44.9 1000 14.5 47.6 1 .5 1.6 10 1.2 3.9 50 3.0 9.8 100 4.3 14.2 200 6.4 21.0 400 9.7 31.7 700 13.7 45.0 900 16.1 52.8 1000 17.3 56.6 1 .5 1.6 10 1.2 3.9 50 3.0 9.8 100 4.3 14.2 200 6.4 21.0 400 9.7 31.7 700 13.7 45.0 900 16.1 52.8 1000 17.3 56.6 for plenum versions of 8240, see 88240 or 82240. 1 .4 1.2 10 1.3 4.3 50 3.1 10.2 100 4.5 14.8 200 6.6 21.7 400 10.0 32.8 700 14.2 46.6 900 16.6 54.5 1000 18.1 59.4 1 .5 1.6 10 1.5 4.9 50 2.9 9.5 100 4.0 13.1 200 5.7 18.7 400 8.5 27.9 700 12.2 40.0 900 14.5 47.6 1000 15.8 51.8 1 .4 1.4 10 1.5 4.9 50 3.7 12.1 100 5.4 17.7 200 8.1 26.6 400 12.4 40.7 700 17.7 58.1 900 21.1 69.2 1000 22.8 74.8 shielding materials nom. dcr nom. imp. ( ? ) nominal core od nominal od inch mm inch mm conductor (stranding) diameter nom. dcr standard unit weight standard lengths lbs. kg ft. m ul nec/ c(ul) cec type part no. mhz db/ 100 ft. db/ 100m nominal attenuation nominal capacitance pf/m pf/ft. nom. vel. of prop. description contact the belden customer service department for a comprehensive connector cross reference. 1-800-belden-1 . request quotation of rg/u cables not listed. see beldens website, www.belden.com, for connector information. teflon is a dupont trademark.
rg-8x type ?16 awg stranded (19x29) .058 bare copper conductor ?bare copper braid shield (95% coverage) gas-injected fpe insulation ?black pvc jacket ul awm 9258 nec: u-500 u-152.4 20.0 9.1 16 awg .155 3.94 bc braid .242 6.15 50 82% 24.8 75.6 style 1354 cm 500 152.4 18.5 8.4 (19x29) 95% shield (30v 80?) cec: u-1000 u-304.8 39.0 17.7 .058 coverage cm 1000 304.8 40.0 18.2 bc 3.3 ? /m 4.3 ? /m 10.8 ? /km 14.1 ? /km 1000 ft. put-up also available in white. suitable for outdoor and aerial applications. rg-8/u type ?13 awg stranded (7x21) .085 bare copper conductor ?bare copper braid shield (97% coverage) polyethylene insulation ?black pvc jacket 75? 8237 nec: 100 30.5 13.6 6.2 13 awg .285 7.24 bc braid .405 10.29 52 66% 28.5 93.5 cmh 500 152.4 58.0 26.3 (7x21) 97% shield cec: 1000 304.8 114.0 51.7 .085 coverage cmh ft1 bc 1.2 ? /m 1.9 ? /m 3.9 ? /km 6.2 ? /km jan-c-17a suitable for outdoor and aerial applications. polyethylene insulation ?black non-contaminating pvc jacket ul awm 9251 nec: 500 152.4 58.0 26.3 13 awg .285 7.24 bc braid .405 10.29 52 66% 28.5 93.5 style 1354 cmx 1000 304.8 115.0 52.3 (7x21) 97% shield (30v 60?) cec: .085 coverage cmx bc 1.2 ? /m 1.9 ? /m 3.9 ? /km 6.2 ? /km mil-c-17d rg-8/u type ?11 awg stranded (7x19) .108 bare copper conductor ?bare copper braid shield (97% coverage) foam polyethylene insulation ?black pvc jacket ul awm 8214 nec: 100 30.5 14.2 6.5 11 awg .285 7.24 bc braid .403 10.24 50 78% 26 85.3 style 1354 cm 500 152.4 61.0 27.7 (7x19) 97% shield (30v 80?) cec: 1000 304.8 121.0 55.0 .108 coverage cm bc 1.1 ? /m 1.2 ? /m 3.6 ? /km 3.9 ? /km suitable for outdoor and aerial applications. bc = bare copper dcr = dc resistance fpe = foam polyethylene hdpe = high-density polyethylene tc = tinned copper contact the belden customer service department for a comprehensive connector cross reference. 1-800-belden-1 . request quotations of rg/u cables not listed. coaxial cables 6.69 6 coaxial cables for more information, contact belden technical support: 1-800-belden-1 ?www.belden.com 50 ohm transmission and computer cable rg-8x and rg-8/u type 1 .3 1.0 10 .9 3.0 50 2.1 6.9 100 3.1 10.2 200 4.5 14.8 400 6.6 21.7 700 9.1 29.9 900 10.7 35.1 1000 11.2 36.7 1.2.5 10 .6 1.8 50 1.3 4.3 100 1.9 6.2 200 2.8 9.2 400 4.2 13.8 700 5.9 19.4 900 6.9 22.6 1000 7.4 24.3 4000 23.2 76.1 1.2.5 10 .6 1.8 50 1.3 4.3 100 1.9 6.2 200 2.8 9.2 400 4.2 13.8 700 5.9 19.4 900 6.9 22.6 1000 7.4 24.3 4000 23.2 76.1 1.1.5 10 .5 1.7 50 1.2 3.9 100 1.7 5.6 200 2.6 8.5 400 3.9 12.8 700 5.6 18.4 900 6.5 21.3 1000 7.0 23.0 4000 21.5 70.5 shielding materials nom. dcr nom. imp. ( ? ) nominal core od nominal od inch mm inch mm conductor (stranding) diameter nom. dcr standard unit weight standard lengths lbs. kg ft. m ul nec/ c(ul) cec type part no. mhz db/ 100 ft. db/ 100m nominal attenuation nominal capacitance pf/m pf/ft. nom. vel. of prop. description
coaxial cables 6.70 for more information, contact belden technical support: 1-800-belden-1 ?www.belden.com rg-8/u type ?10 awg solid .108 bare copper conductor ?duobond ii + tinned copper braid shield (90% coverage) semi-solid polyethylene insulation ?black pvc jacket low loss 9913 100 30.5 14.2 6.4 10 awg .286 7.26 duobond ii* .405 10.29 50 84% 24.6 80.7 80? 250 76.2 31.8 14.4 (solid) + 90% 500 152.4 57.0 25.9 .108 tc braid 1000 304.8 116.0 52.6 bc 1.8 ? /m .9 ? /m 5.9 ? /km 3.0 ? /km suitable for outdoor and aerial applications. plenum ?semi-solid fep insulation ?black fluorocopolymer jacket 150? 89913 nec: 500 ? 152.4 63.0 28.6 10 awg .295 7.49 duobond ii* .364 9.25 50 83% 25.0 82.0 cmp 1000 ? 304.8 128.0 58.2 (solid) + 90% cec: .108 tc braid cmp ft6 bc 1.8 ? /m .9 ? /m 5.9 ? /km 3.0 ? /km rg-8/u type ?10 awg stranded (7x19) .108 bare copper conductor ?duobond ii + tinned copper braid shield (95% coverage) gas-injected foam hdpe insulation ?matte black belflex jacket low loss 9913f7 100 30.5 12.5 5.7 10 awg .285 7.24 duobond ii* .405 10.29 52 85% 22.5 80.7 high-flex 250 76.2 27.8 12.6 (7x19) + 95% tc 80? 500 152.4 52.5 23.8 .108 braid 1000 304.8 104.0 47.2 bc 1.8 ? /m 1.1 ? /m 5.9 ? /km 3.7 ? /km suitable for outdoor and aerial applications. rg-8/u type ?10 awg solid .103 bare copper conductor ?duobond ii + tinned copper braid shield (95% coverage) gas-injected foam hdpe insulation ?black pvc jacket low loss 9914 nec: 500 152.4 56.0 25.4 10 awg .285 7.24 duobond ii* .403 10.24 50 82% 24.8 81.4 ul awm cmg 1000 304.8 114.0 51.7 (solid) + 95% style 1354 cec: .103 tc braid (30v 80?) cmg ft4 bc 1.1 ? /m 1.8 ? /m 3.6 ? /km 3.9 ? /km suitable for outdoor and aerial applications. rg-8/u type ?10 awg solid .108 bare copper conductor ?duofoil (100% coverage) + tinned copper braid shield (90% coverage) plenum ?foam fep insulation ?black fluorocopolymer jacket low loss 7733a nec: 500 152.4 53.5 24.3 10 awg .280 7.11 duofoil .355 9.01 50 84% 24.2 79.4 125? cmp 1000 304.8 105.0 47.7 (solid) + 90% cec: .108 tc braid cmp ft6 bc 1.8 ? /m .9 ? /m 5.9 ? /km 3.0 ? /km suitable for outdoor and aerial applications. bc = bare copper dcr = dc resistance fep = fluorinated ethylene propylene hdpe = high-density polyethylene tc = tinned copper contact the belden customer service department for a comprehensive connector cross reference. 1-800-belden-1 . request quotations of rg/u cables not listed. *duobond ii = bonded duofoil (100% coverage) + aluminum braid (67% coverage). ? spools are one piece, but length may vary ?0% from length shown. 50 ohm transmission and computer cable rg-8/u type 1 .4 1.3 10 .5 1.7 50 1.0 3.3 100 1.4 4.6 200 1.8 6.0 400 2.6 8.5 700 3.6 11.8 900 4.1 13.5 1000 4.4 14.4 4000 9.9 32.5 1.1.3 10 .4 1.3 50 1.0 3.3 100 1.6 5.2 200 2.3 7.5 400 3.4 11.1 700 5.0 16.4 900 6.0 19.7 1000 6.9 22.6 4000 17.0 55.8 1.1.3 10 .4 1.3 50 1.1 3.6 100 1.5 4.9 200 2.1 6.9 400 3.2 10.5 700 4.5 14.8 900 5.7 18.7 1000 5.9 19.4 4000 14.1 46.3 for plenum version of 9913, see 89913. 1 .4 1.3 10 .6 2.0 50 1.1 3.6 100 1.5 4.9 200 2.0 6.6 400 3.0 9.8 700 4.0 13.1 900 4.7 15.4 1000 5.0 16.4 4000 12.1 39.7 shielding materials nom. dcr nom. imp. ( ? ) nominal core od nominal od inch mm inch mm conductor (stranding) diameter nom. dcr standard unit weight standard lengths lbs. kg ft. m ul nec/ c(ul) cec type part no. mhz db/ 100 ft. db/ 100m nominal attenuation nominal capacitance pf/m pf/ft. nom. vel. of prop. description 1 .3 1.0 10 .5 1.7 50 1.0 3.3 100 1.4 4.6 200 1.8 6.0 400 2.6 8.5 700 3.6 11.8 900 4.1 13.5 1000 4.4 14.4 4000 9.5 31.1
coaxial cables 6.71 6 coaxial cables for more information, contact belden technical support: 1-800-belden-1 ?www.belden.com 50 ohm transmission cable electrical characteristics of 9913, 9913f7 and 9914 frequency (mhz) attenuation attenuation (db/100 ft.) 100.0 10.0 1.0 .1 1 10 100 1000 10000 9913f7, 9914 9913 frequency (mhz) power rating watts 10000 1000 100 10 1 10 100 1000 10000 9913f7, 9914 9913