Part Number Hot Search : 
PT570524 SI9750 LM317 0000X H8S2148 2SA1955 0NM60 H100J
Product Description
Full Text Search
 

To Download C-2098190-1 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  3 revisions 0 plc 1 plc 2 plc 3 plc 4 plc angles of scale sheet rev name size cage code drawing no dimensions: tolerances unless otherwise specified: dwn chk apvd material finish product spec application spec weight p ltr date apvd dwn description 4 2 1 d b a a b c c d all rights reserved. released for publication c copyright this drawing is unpublished. 1471-9 (3/13) a2 restricted to this drawing is a controlled document. te connectivity customer drawing 2098190-1 a. lee 25may2010 a. lee 25may2010 a. lee 25may2010 1:1 1 1 d - - - - - inches - - .01 .005 - 1$ relay, evc500 spst-no 12v - 20 20 00779 by - - - c revised per eco-12-015617 28aug2012 dd al d revised per eco-15-005163 02apr2015 dd al 2.20 #.025 [55.81 #0.63] [52.0 #0.51] 2.05 .02 [42.0 #0.26] 1.65 .01 2.688 #.01 [68.28 #0.26] [26.67#0.26] 1.05 [80.48 #0.26] 3.17 .01 [12.6 #0.26] .50 .01 .55 #.025 [14.04 #0.63] 2.85 #.025 [72.3 #0.63] 2.44#.02 [62.0#0.51] 2098190-1 part number coil wire is 22awg with 15.3 in [390mm] length black = "-" coil red = "+" coil 1. to avoid overheating, the coil above should not be left on at full power (12v) for a long period of time. 2. the minimum hold current of 650ma (mentioned above) only produces a t-rise of 20$c (max). 3. for any other information, please refer to the ev200 general customer datasheet. performance data contact arrangement: power contacts 1 form x (spst-no-dm) rated operating voltage vdc 100 - 900 (note: voltages between 450 to 900 vdc are capable but load dependent and require te engineering approval) continuous (carry) current, typical a 500 @ 65$c, 400 mcm conductors consult factory for required conductors for higher (500+ a) currents break current at 320 vdc a 2,000, 1 cycle contact resistance, typical ( @ 200a) mohms 0.2 load life cycles see chart mechanical life cycles 1,000,000 operate time @ 25$c close (includes bounce), typical ms 15 bounce (after close only), max ms 7 release (includes arcing), max @ 2000a ms 12 dielectric withstand voltage vrms 2,200 @ sea level (leakage<1 ma) insulation resistance @ 500 vdc megohms 100 (50 at end of life) shock, 11ms 1/2 sine, peak, operating g 20 vibration, sine, 80 - 200 hz, peak g 20 operating ambient temperature $c -40$ to +85$ weight (nominal) lb [kg] .95 [0.43] voltage (will operate) 9 - 36 vdc voltage (max) 36 vdc pickup (close) voltage (max) 9 vdc hold voltage (min) 7.5 vdc dropout (open) voltage (min) 6 vdc inrush current (max) 3.8a holding current (avg) 0.13a @ 12v inrush time (max) 130 ms parameters units value for ev200 series coil data label stainless m8 x 1.25 power terminals (hardware supplied): 2 x m8 washer, stainless 2 x m8 lockwasher - split ring, stainless 2 x m8 x 1.25 nut, stainless torque 80 to 100 in-lb [8.8 to 11 nm] a2 "-" negative terminal a1 "+" positive terminal mounting hardware (not supplied): 2 x m5 bolt 2 x m5 lockwasher 2 x m5 narrow washer torque 15 to 30 in-lb [1.7 to 3.3 nm]


▲Up To Search▲   

 
Price & Availability of C-2098190-1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X