  page 1/12 21october2014/version 3 lem reserves the right to carry out modifcations on its transducers, in order to improve them, without prior notice www.lem.com for the electronic measurement of current: dc, ac, pulsed..., with galvanic separation between the primary and the secondary circuit. features hall effect measuring principle galvanic separation between primary and secondary circuit insulated test voltage 4300 v low power consumption single power supply +5 v fixed offset & sensitivity over-current detect 2.63 i pn (peak value) memory check. advantages small size and space saving only one design for wide primary current range high immunity to external interference 8 mm creepage /clearance high insulation capability fast response. applications ac variable speed drives static converters for dc motor drives battery supplied applications uninterruptible power supplies (ups) switched mode power supplies (smps) power supplies for welding applications the solar inverter on dc side of the inverter (mppt) combiner box. standards en 50178: 1997 iec 61010-1: 2010 iec 61326-1: 2012 ul 508: 2010. application domain industrial. current transducer ho-p series i pn = 6, 10, 25 a ref: ho 6-p, ho 10-p, ho 25-p n74.54.09.000.0, n74.54.13.000.0, n74.54.19.000.0
page 2/12 21october2014/version 3 lem reserves the right to carry out modifcations on its transducers, in order to improve them, without prior notice www.lem.com absolute maximum ratings parameter symbol unit value supply voltage (not operating) u c v 6.5 primary conductor temperature t b c 125 esd rating, human body model (hbm) u esd kv 2 stresses above these ratings may cause permanent damage. exposure to absolute maximum ratings for extended periods may degrade reliability. ul 508: ratings and assumptions of certifcation file # e189713 volume: 2 section: 5 standards csa c22.2 no. 14-10 industrial control equipment - edition 11 - revision date 2011/08/01 ul 508 standard for industrial control equipment - edition 17 - revision date 2010/04/15 ratings parameter symbol unit value primary involved potential v ac/dc 600 max surrounding air temperature t a c 105 primary current i p a according to series primary currents secondary supply voltage u c v dc 5 output voltage v out v 0 to 5 conditions of acceptability when installed in the end-use equipment, consideration shall be given to the following: 1 - these devices have been evaluated for overvoltage category iii and for use in pollution degree 2 environment. 2 - a suitable enclosure shall be provided in the end-use application. 3 - the terminals have not been evaluated for feld wiring. 4 - these devices have been evaluated for use in 105c maximum surrounding air temperature. 5 - the secondary (sensing) circuit is intended to be supplied by a isolated secondary circuit - limited voltage circuit defned by ul 508 paragraph 32.5. the maximum open circuit voltage potential available to the circuit and overcurrent protection shall be evaluated in the end use application. 6 - these devices are intended to be mounted on a printed wiring board of end-use equipment. the suitability of the connections (including spacings) shall be determined in the end-use application. 7 - any surface of polymeric housing have not been evaluated as insulating barrier. 8 - low voltage circuits are intended to be powered by a circuit derived from an isolating source (such as a transformer , optical isolator, limiting impedance or electro-mechanical relay) and having no direct connection back to the primary circuit (other than through the grounding means). marking only those products bearing the ul or ur mark should be considered to be listed or recognized and covered under ul's follow-up service. always look for the mark on the product. ho-p series
page 3/12 21october2014/version 3 lem reserves the right to carry out modifcations on its transducers, in order to improve them, without prior notice www.lem.com insulation coordination parameter symbol unit value comment rms voltage for ac isolation test 50/60 hz/1 min 1) u d kv 4.3 impulse withstand voltage 1.2/50 s ? w kv 8 partial discharge extinction voltage @ 10 pc (rms) u e v 1650 clearance (pri. - sec.) d ci mm 8 shortest distance through air creepage distance (pri. - sec.) d cp mm 8 shortest path along device body case material v0 according to ul 94 comparative tracking index cti 600 application example - - 600 v cat iii pd2 reinforced insulation, non uniform feld according to en 50178 application example - - 300 v cat iii pd2 reinforced insulation, non uniform feld according to iec 61010 application example - - 1000 v cat iii pd2 simple insulation, non uniform feld according to en 50178, iec 61010 environmental and mechanical characteristics parameter symbol unit min typ max comment ambient operating temperature t a c -40 105 ambient storage temperature t s c -40 105 surrounding temperature according to ul 508 c 105 mass m g 10 note : 1) voltage of retention pins has to be consider. if it is same as primary electrical potential, insulation is no issue. if it is same as secondary electrical potental, insulation of primary bus bar has to be considered. ho-p series
page 4/12 21october2014/version 3 lem reserves the right to carry out modifcations on its transducers, in order to improve them, without prior notice www.lem.com electrical data i pn = 6 a at t a = 25 c, c = +5 v, p = 1 turn, l = 10 k? unless otherwise noted (see min, max, typ. defnition paragraph in page 7). parameter symbol unit min typ max comment primary nominal rms current i pn a 6 primary current, measuring range i pm a -20 20 supply voltage c v 4.5 5 5.5 current consumption i c ma 19 25 reference voltage ref v 2.475 2.5 2.525 internal reference external reference voltage ref v 0.5 2.65 output voltage range @ i pm v out - v ref v -2 2 output voltage @ i p = 0 a v out v v ref + oe electrical offset voltage oe mv -10 10 temperature coeffcient of ref ref ppm/k 160 -20 c .. 85 c internal reference 190 -40 c .. 105 c internal reference temperature coeffcient of oe tcv oe mv/k 0.14 -20 c .. 85 c -40 c .. 105 c theoretical sensitivity th mv/a 100 600 mv/ i pn @ c = 5 v sensitivity error g % 0.85 factory adjustement temperature coeffcient of ppm/k 250 linearity error 0 .. i pn l % of i pn 0.5 @ c = 5 v linearity error 0 .. i pm l % of i pm 0.8 @ c = 5 v gain error with respect to c 10 % %/% 0.05 gain error per c drift magnetic offset voltage @ i p = 0 after 2.5 i pn v om mv 5 reaction time @ 10 % of i pn t ra s 2 d i /d t = i pn /s response time @ 90 % of i pn t r s 3.5 d i /d t = i pn /s frequency bandwidth (-3 db) khz 250 output voltage noise (spectral density) (dc .. 100 khz) no vrms/hz 32.9 @ c = 5 v output voltage noise (dc .. 20 mhz) no mvpp 80 over-current detect v 2.6 i pn 2.9 i pn 3.2 i pn peak value accuracy @ i pn % of i pn 1.35 g + l accuracy @ i pn @ a = +85c % of i pn 4.25 see formula note 1) accuracy @ i pn @ a = +105c % of i pn 5.22 see formula note 1) note : 1) accuracy @ i p and ta = [ + ( /10000) ( a - 25) + oe 100 ( a -25) / ( th i p )]. ho-p series
page 5/12 21october2014/version 3 lem reserves the right to carry out modifcations on its transducers, in order to improve them, without prior notice www.lem.com electrical data i pn = 10 a at t a = 25 c, c = +5 v, p = 1 turn, l = 10 k? unless otherwise noted (see min, max, typ. defnition paragraph in page 7). parameter symbol unit min typ max comment primary nominal rms current i pn a 10 primary current, measuring range i pm a -25 25 supply voltage c v 4.5 5 5.5 current consumption i c ma 19 25 reference voltage ref v 2.475 2.5 2.525 internal reference external reference voltage ref v 0.5 2.65 output voltage range @ i pm v out - v ref v -2 2 output voltage @ i p = 0 a v out v v ref + oe electrical offset voltage oe mv -10 10 temperature coeffcient of ref ref ppm/k 160 -20 c .. 85 c internal reference 190 -40 c .. 105 c internal reference temperature coeffcient of oe tcv oe mv/k 0.12 theoretical sensitivity th mv/a 80 800 mv/ i pn , @ c = 5 v sensitivity error g % 0.85 factory adjustement temperature coeffcient of ppm/k 250 linearity error 0 .. i pn l % of i pn 0.5 @ c = 5 v linearity error 0 .. i pm l % of i pm 0.8 @ c = 5 v gain error with respect to c 10 % %/% 0.05 gain error per c drift magnetic offset voltage @ i p = 0 after 2.5 i pn v om mv 6 reaction time @ 10 % of i pn t ra s 2 d i /d t = i pn /s response time @ 90 % of i pn t r s 3.5 d i /d t = i pn /s frequency bandwidth (-3 db) khz 250 output voltage noise (spectral density) (dc .. 100 mhz) no vrms/hz 17.5 output voltage noise (dc .. 20 mhz) no mvpp 50 over-current detect v 2.6 i pn 2.9 i pn 3.2 i pn peak value accuracy @ i pn % of i pn 1.35 g + l accuracy @ i pn @ a = +85 c % of i pn 3.75 see formula note 1) accuracy @ i pn @ a = +105 c % of i pn 4.55 see formula note 1) note : 1) accuracy @ i p and ta = [ + ( /10000) ( a - 25) + oe 100 ( a -25) / ( th i p )]. ho-p series
page 6/12 21october2014/version 3 lem reserves the right to carry out modifcations on its transducers, in order to improve them, without prior notice www.lem.com electrical data i pn = 25 a at t a = 25 c, c = +5 v, p = 1 turn, l = 10 k? unless otherwise noted (see min, max, typ. defnition paragraph in page 7). parameter symbol unit min typ max comment primary nominal rms current i pn a 25 primary current, measuring range i pm a -62.5 62.5 supply voltage c v 4.5 5 5.5 current consumption i c ma 19 25 reference voltage ref v 2.475 2.5 2.525 internal reference external reference voltage ref v 0.5 2.65 output voltage range @ i pm v out - v ref v -2 2 output voltage @ i p = 0 a v out v v ref + oe electrical offset voltage oe mv -10 10 temperature coeffcient of ref ref ppm/k 160 -20 c .. 85 c internal reference 190 -40 c .. 105 c internal reference temperature coeffcient of oe tcv oe mv/k 0.075 theoretical sensitivity th mv/a 32 800 mv/ i pn @ c = 5 v sensitivity error g % 0.85 factory adjustement temperature coeffcient of ppm/k 250 linearity error 0 .. i pn l % of i pn 0.5 @ c = 5 v linearity error 0 .. i pm l % of i pm 0.8 @ c = 5 v gain error with respect to c 10 % %/% 0.05 gain error per c drift magnetic offset voltage @ i p = 0 after 2.5 i pn v om mv 7 reaction time @ 10 % of i pn t ra s 2 d i /d t = i pn /s response time @ 90 % of i pn t r s 3.5 d i /dt = i pn /s frequency bandwidth (-3 db) khz 250 output voltage noise (spectral density) (dc .. 100 mhz) no vrms/hz 10.5 output voltage noise (dc .. 20 mhz) no mvpp 30 over-current detect v 2.6 i pn 2.9 i pn 3.2 i pn peak value accuracy @ i pn % of i pn 1.35 g + l accuracy @ i pn @ a = +85 c % of i pn 3.42 see formula note 1) accuracy @ i pn @ a = +105 c % of i pn 4.1 see formula note 1) note : 1) accuracy @ i p and ta = [ + ( /10000) ( a - 25) + oe 100 ( a -25) / ( th i p )]. ho-p series
page 7/12 21october2014/version 3 lem reserves the right to carry out modifcations on its transducers, in order to improve them, without prior notice www.lem.com defnition of typical, minimum and maximum values minimum and maximum values for specified limiting and safety conditions have to be understood as such as well as values shown in typical graphs. on the other hand, measured values are part of a statistical distribution that can be specified by an interval with upper and lower limits and a probability for measured values to lie within this interval. unless otherwise stated (e.g. 100 % tested), the lem definition for such intervals designated with min and max is that the probability for values of samples to lie in this interval is 99.73 %. for a normal (gaussian) distribution, this corresponds to an interval between -3 sigma and +3 sigma. if typical values are not obviously mean or average values, those values are defined to delimit intervals with a probability of 68.27 %, corresponding to an interval between -sigma and +sigma for a normal distribution. typical, maximal and minimal values are determined during the initial characterization of a product. ho-p series
page 8/12 21october2014/version 3 lem reserves the right to carry out modifcations on its transducers, in order to improve them, without prior notice www.lem.com maximum continuous dc primary current figure 1: i p vs t a for ho series important notice : whatever the usage and/or application, the primary conductor temperature shall not go above the maximum rating of 125 c as stated in page 2 of this datasheet. 0 10 20 30 40 50 0 25 50 75 100 125 i p (a) t a ( ) 15a 15a 15a 15a 15a 15a 15a ho 6 0 12.5 25 37.5 50 62.5 0 25 50 75 100 125 i p (a) t a ( ) 15a 15a 15a 15a 15a 15a 15a ho 10 0 25 50 75 100 0 25 50 75 100 125 i p (a) t a ( ) ho 25 ho-p series
page 9/12 21october2014/version 3 lem reserves the right to carry out modifcations on its transducers, in order to improve them, without prior notice www.lem.com measuring range with external reference voltage upper limit: i p = -10 v ref +45 (v ref = 0.5 .. 2.65 v) lower limit: p = -10 v ref +5 (v ref = 0.5 .. 2.65 v) upper limit: i p = -12.5 v ref +56.25 (v ref = 0.5 .. 2.65 v) lower limit: p = -12.5 v ref +6.25 (v ref = 0.5 .. 2.65 v) upper limit: t a = 105 c i p = 75 (v ref = 0.5 ..2.1 v) i p = 31.25 v ref +140.63 (v ref = 2.1 .. 2.65 v) t a = 85 c i p = 80 (v ref = 0.5 ..1.94 v) i p = 31.25 v ref +140.63 (v ref = 1.94 .. 2.65 v) t a = 60 c i p = 90 (v ref = 0.5 ..1.62 v) i p = 31.25 v ref +140.63 (v ref = 1.62 .. 2.65 v) t a = 25 c i p = 95 (v ref = 0.5 ..1.46 v) i p = 31.25 v ref +140.63 (v ref = 1.46 .. 2.65 v) lower limit: p = -31.25 v ref +15.63 (v ref = 0.5 .. 2.65 v) example with v ref = 0.5 v: the 6 a version has a measuring range from 0 a to 40 a the 10 a version has a measuring range from 0 a to 50 a the 25 a version has a measuring range from 0 a to 75 a at t a = 105 c example with v ref = 1.5 v: the 6 a version has a measuring range from -10 a to 30 a the 10 a version has a measuring range from -18.7 a to + 56.3 a the 25 a version has a measuring range from -31.2 a to + 80 a at t a = 85 c -30 -20 -10 0 10 20 30 40 50 0.5 1 1.5 2 2.5 i p (a) v ref (v) ho 6 -40 -30 -20 -10 0 10 20 30 40 50 60 0.5 1 1.5 2 2.5 i p (a) v ref (v) ho 10 -90 -60 -30 0 30 60 90 120 0.5 1 1.5 2 2.5 ip (a) v ref (v) ho 25 25 60 85 105 ho-p series
page 10/12 21october2014/version 3 lem reserves the right to carry out modifcations on its transducers, in order to improve them, without prior notice www.lem.com pcb footprint assembly on pcb ? recommended pcb hole diameter 1.5 mm for retention pin 0.9 mm for secondary pin ? maximum pcb thickness 2.4 mm ? wave soldering profle maximum 260 c, 10 s no clean process only safety this transducer must be used in limited-energy secondary circuits according to iec 61010-1. this transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturers operating instructions. caution, risk of electrical shock. when operating the transducer, certain parts of the module can carry hazardous voltage (e.g. primary bus bar, power supply). ignoring this warning can lead to injury and/or cause serious damage. this transducer is a build-in device, whose conducting parts must be inaccessible after installation. a protective housing or additional shield could be used. main supply must be able to be disconnected. ho-p series
page 11/12 21october2014/version 3 lem reserves the right to carry out modifcations on its transducers, in order to improve them, without prior notice www.lem.com figure 2: current cycle used to measure magnetic and electrical offset (transducer supplied) electrical offset the electrical offset v oe can either be measured when the ferro-magnetic parts of the transducer are: completely demagnetized, which is diffcult to realize, or in a known magnetization state, like in the current cycle shown in fgure 2. using the current cycle shown in fgure 18, the electrical offset is: note: the transducer has to be demagnetized prior to the application of the current cycle (for example with a demagnetization tunnel). overall accuracy the overall accuracy at 25 c x g is the error in the - i pn .. + pn range, relative to the rated value pn . it includes: the electrical offset v oe the sensitivity error g the linearity error l (to i pn ) (%) response and reaction times the response time t r and the reaction time t ra are shown in fgure 18. both depend on the primary current d i/ d t . they are measured at nominal ampere-turns. figure 3: response time t r and reaction time t ra ampere-turns and amperes the transducer is sensitive to the primary current linkage p (also called ampere-turns). p = n p p (at) where n p is the number of primary turn (depending on the connection of the primary jumpers) caution: as most applications will use the transducer with only one single primary turn ( n p = 1), much of this datasheet is written in terms of primary current instead of current linkages. however, the ampere-turns (at) unit is used to emphasis that current linkages are intended and applicable. transducer simplifed model the static model of the transducer at temperature t a is: v out = g p + overall error (mv) in which error = g p g + l p g + tcg ( t a -25) p g + v oe + tcv oe ( t a -25) (mv) with: p = n p p : primary current linkage (at) p max : max primary current linkage applied to the transducer (a/t) v out : output voltage (v) t a : ambient operating temperature (c) v oe : electrical offset voltage (v) tcv oe : temperature coeffcient of v oe (mv/k) g : sensitivity of the transducer (v/at) tcg : temperature coeffcient of g (%/k) g : sensitivity error (%) l : linearity error for p (%) this model is valid for primary ampere-turns p between - p max and + p max only. sensitivity and linearity to measure sensitivity and linearity, the primary current (dc) is cycled from 0 to p , then to - p and back to 0 (equally spaced p /10 steps). the sensitivity g is defned as the slope of the linear regression line for a cycle between pn . the linearity error l is the maximum positive or negative difference between the measured points and the linear regression line, expressed in % of pn . magnetic offset the magnetic offset voltage v om is the consequence of a current on the primary side (memory effect of the transducers ferro- magnetic parts). it is measured using the following primary current cycle. v om depends on the current value p1 ( i p1 > i pm ). performance parameters defnition t v t v v out out o m 2 ) ( ) ( 2 1 ? = p ( dc) - i p 1 p 1 0 a t 1 t t i p ( 3 ) t 2 i p ( 3 ) i i t ra v t r 90 % 10 % t 100 % i i out p 2 ) ( ) ( 2 1 t v t v v out out oe + = ) 25 ( ) ( ) ( c ... t ... t ... oe oe ot ? = ho-p series
page 12/12 21october2014/version 3 lem reserves the right to carry out modifcations on its transducers, in order to improve them, without prior notice www.lem.com 1 2 3 4 5 47nf 47nf + u c 4. 7nf v o u t v re f ( i n / ou t) oc d 0v > 10k i n ou t 5 200 i p operation principle d ci d cp + u c v re f v o u t 0v oc d ( i n / ou t) dimensions ho 6-p, ho 10-p, ho 25-p (mm, general linear tolerance 0.5 mm) remarks there are 6 retention pins which have to be used only for retention as well as into the section called "assembly on pcb". the pimary conductor to be measured should go through the aperture 8 8 mm. ho-p series


▲Up To Search▲   

 
Price & Availability of HO10-P

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X