linkcom manufacturing co., ltd *,# =see notes below model specification ** * * * * (6)load regulation measured from 20% to full load. (7)line regulation measured from 100 vac to 277vac. (8)preset accuracy measured at norma l load, 120vac input. reference rohs compliant safety: ul emc: meet ce comply with indoor/outdoor waterproof (ip 67) dimension (l*w*h): 208.4 * 72 * 38.55 mm dimension (l*w*h): 8.2 * 2.83 * 1.52 inch lcch-080 360 1 ac input 90~305vac protection: scp / otp / ovp power factor:>0.98@115vac;>0.95@230vac;@full load high operating ambient temp: -30 ~+60 (refer to output dreating curve) min. nrom. max. 30 36 2.3 i/p-o/p, i/p-fg,o/p-fg :100m ohms / 500vdc / 25 / 70% rh 208.4 * 72 * 38.5 mm 8.2 * 2.83 * 1.52 inch meet ce en55015 i/p-o/p 3.75kvac, o/p-grnd 0.5kvac, i/p-grnd 1.88kvac (9)100% production tested. (5)minimum load is not required for proper operation . notes (1)all parameters not specially mentioned are measu red 230vac input. (2)all specifications typical @25 , unless otherwise noted, at normal line and load. (3)ripple and noise measured directl y at pins/terminals at nom. load, 0.1uf bypass and 47uf electrolytic, pk-pk @20mhz bandwidth. (4)specified for free-air convection cooling. dimensions(l*w*h) storage temperature hold up time over v, protection emi withstand voltage isolation resistance operating temp.*(4) leakage current over temp. protection 25ms at full load 115vac/230vac short circuit protection 1.5a/115vac 0.56a/230vac cold start 65a @ 230vac ac current *(9) <0.45ma/277vac short circuit protection will restart automatically after the fault condition is removed module : lcch-080 360 features preset accuracy (%) *(8) safety relative humidity -30 to +60 @full load( refer to output derating curve) -40 to +80 10 to +90%, non-cond. temp. coefficient 0.03% / (0-50 , typ) ul60950-1 dc output power efficiency(typ @full load) active power factor o/p noise (p-p, mv) *(3) setup,rise time(typ.) load regulation (%) *(6) input voltage range input frequency dc output voltage range (v) line regulation (%) *(7) 2s,500ms at full load 115vac/230vac shut down and latch off o/p voltage , re-power on t o recover 90-305vac, 127-431vdc, normal 100-277vac range:47-63hz, normal 50-60hz pf>0.95 @230vac, pf>0.98@115vac at full load and ra ted output voltage output current(a) *(5) inrush current (typ) model no. part no. power supply 208.4 * 72 * 38.55 mm 8.2 * 2.83 * 1.52 inch lcch-080 360 plcch0080 360 model name size 500 90% 82.8 w 11 www.linkcom.com.tw for more information, please contact with: sales@ linkcom.com.tw
linkcom manufacturing co., ltd model no. part no. power supply 208.4 * 72 * 38.55 mm 8.2 * 2.83 * 1.52 inch lcch-080 360 plcch0080 360 model name size reference unit :mm inch derate dimensions www.linkcom.com.tw for more information, please contact with :sales @ linkcom.com.tw
|