Part Number Hot Search : 
CSD3120H UJA1076 6024907 KK90GB80 55T10 SK208 70V25 330M10
Product Description
Full Text Search
 

To Download CAR0812FP Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  www.lineagepower.com/oem lineage power lineage power lineage power (china) 601 shiloh rd. 2841 dow avenue 3f, #9 building, #456 hong cao road plano, tx 75074 tustin, ca 92780 usa shanghai 200233, china phone: +1.972.244.9722 phone: +1.714.544 6665 phone: +86.021.54279977*808 rev 100728 ? compact 1u pro le ? high ef ciency design optimized for mid to light load applications ? constant current characteristic ? n+1 redundancy with warm plug capability (iec-320 ac inlet) ? high power density (18w/in3) ? 3.3vsb, active load sharing, i2c and pmbus standard interface, remote on/off and remote sense functions key market segments & applications ? distributed power  blade servers ? mid-end servers  network equipment ? network attached storage ? storage area networks specifications 850 watt +12v front end power supply input voltage range 85-264 vac, 47-63 hz, derate to 750w for <90vac input input current maximum 11a (full load, vin = 100vac) / 12a (full load, vin = 90vac) inrush current 40a max. cold start (measured at 25oc for all line conditions typical duration 10ms) input protection single fuse (line) ? 15a & 250vac (type 3ab axial) power factor 0.99 typical at full load, complies with iec555, en60555-2, en61000-3-2 ef ciency up to 92.5% ef ciency at 50% load and 230 vac operation output power 850w derate to 750w for <90vac input output voltage range 10.8~13.2 vdc with remote programming output current 71.0a @ 12v (no minimum load required) standby bias voltage 3.3vsb@1a (optional 5vsb) voltage regulation 2% of vnom for any combination of line, load and temperature output ripple & noise 1% (pk-pk) @ 20mhz with 0.1 f ceramic and 10 f electrolytic caps at the output transient response 5% max deviation recovery time 500 s @ 50% load step and di/dt < 1a/ s (for system loads >10%) hold-up time 12ms at 850w typical (early warning: 2ms) remote on/off on if >3v or open; off if <1v (max. sink 1ma) open collector type current limit protection adjustable via i2c interface or pmbus, constant current characteristic & power limited to 850w short circuit protection self protected with auto recovery over voltage protection trip level >+14.8vdc 1v, reset condition by recycling the ac input or applying remote on/off operating temperature -10c to +70c. derate above 50c at 2.5%/c (startup -40 c, meet speci ed spec with 30min. warm period) over temperature protection non-latching, thermal shutdown point is set for 125c and recovery point is 110c emi fcc-b & en55022-b with speci ed lter or at rack level, gr-1089-core led indicators ac ok (green) / dc ok (green) / thermal alarm (orange) / fault (red), ?all on one led? tri-color led analog status & control voltage programming (v prog), load sharing (i share), remote on/off, current monitor (i monitor), ac o k, dc ok, temperature warning, fault, ps present, module enable digital status & control i 2 c option and pmbus, see detailed speci cation for details shock & vibration nebs gr-63-core level 3 dimensions 8.73 x 3.38 x 1.61? / 221.7 x 85.9 x 40.9mm weight 4.28 lb. / 1.94 kg. safety approvals iec/ul/csa/en60950-1, ce mark (lvd), tuv features benefits high power density 18w/in 3 more system space for application circuits and hardware load sharing & fault tolerant excellent reliability in n+1 operation automatic fan speed control reduces audible noise and increases reliability system scalability up to 3.2kw allows exibility with minimum investment universal input & international certi cations reduces logistical costs CAR0812FP series 850 watt +12v front end power supply 850 watt +12v front end power supply features:
www.lineagepower.com/oem lineage power lineage power lineage power (china) 601 shiloh rd. 2841 dow avenue 3f, #9 building, #456 hong cao road plano, tx 75074 tustin, ca 92780 usa shanghai 200233, china phone: +1.972.244.9722 phone: +1.714.544 6665 phone: +86.021.54279977*808 rev 100728 efficiency curve: outline drawing connector drawing: d c b a 1 2 3 4 5 6 p 1 p3 p4 p2 pin out information a1 vsb 3.3v b4 ps present d1 vprog p1 +vout a2 vsb 3.3v return b5 sda (i2c bus) d2 n/a p2 +vout a3 signal return b6 scl (i2c bus) d3 remote on/off p3 output return a4 write protect c1 ishare d4 dc ok p4 output return a5 remote sense + c2 n/c d5 ac ok a6 remote sense - c3 n/a d6 interrupt (/sm balert) b1 fault c4 i2c address (a0) b2 n/a c5 i2c address (a1) b3 module enable c6 i2c address (a2) part number definition guide: example: CAR0812FPbz0-1a 850w/12v front end, bezel, 6 of 6 rohs fci berg p/n: 51722-10402400ablf / lineage power part number 82 2024 mating connector: 51762-10402400ablf / lineage power part numbe r 822089 all dimensions in inches (mm) tolerance: .xx = .02 in (.50 mm) .xxx = .010 in (.254 mm) CAR0812FP series 850 watt +12v front end power supply 0% 20% 30% 50% 75% 100% load efficiency 100% 90% 80% 70% 60% 90% 91% 92.5% 91% 90% 82.5% 10% 87% 89% 90% 89% 88% 83% 230 vac 115 vac


▲Up To Search▲   

 
Price & Availability of CAR0812FP

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X