  Datasheet File OCR Text:
  (1/8) 002-02 / 20060413 / ea111_RKY.fm ? all specifications are subject to change without notice. ac input single output, long life, three-phase input ul/c-ul approved r series RKY(1.5kw) the RKY series has 200v three-phase input specifications com- patible with a large output of 1.5kw. this makes it possible to use high power without having to worry about the current limitations of ac lines. in addition, the size of this series is very compact; 92 120 237mm. these products can now be installed in narrow spaces that previously seemed impossible features  built-in, wide-range variable output function.  approved by safety standards (ul, c-ul). conforms to the electrical appliance and material safety law.  conforms to standards for noise terminal voltage vcci-a and en55022-a, for immunity en61000-4-2, 3, 4, 5, 6, 8, 11 and en61000-6-2.  5-year limited warrantee  it is a product conforming to rohs directive. applications  semiconductor fabrication equipment  communication devices  information processing devices part numbers and ratings conformity to rohs directive output voltage(v) 1500w current(a) part no. 24 50 RKY24-50r 36 42 RKY36-42r 48 32 RKY48-32r  conformity to rohs directive: this means that, in conformity with eu directive 2002/95/ec, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, pbb and pbde, have not been used, except for exempted applications.
(2/8) 002-02 / 20060413 / ea111_RKY.fm  all specifications are subject to change without notice. RKY1500w type specifications and standards ? 1 current rating(maximum output current) is determined for ?10 to +65c. derating is required when used outside this temperature range or when used with a 100v system. ? 2 short +rc and ?rc when not using remote control. ? 3 short +s/?s and +/? output terminal when not using variable output voltage. ? 4 short rev and rv when not using variable output voltage. part no. RKY24-50r RKY36-42r RKY48-32r rated output voltage and current ? 1 24v  50a 36v  42a 48v  32a maximum output power w 1200 1512 1536 input conditions input voltage eac v 85 to 265[rated: 100-240] input frequency hz 47 to 66[rated: 50-60](three phase) input current a 4typ./5max. 5typ./6max. 5typ./6max. fuse rating a 15[built-in] 15[built-in] 15[built-in] surge current a 35max.[ac.200-240v, reset after 30s minimum.] leakage current ma 1.3max./1.9max.[when operating: ac.240v, 60hz, according to ice60990-1 fig.13/without phase: ac.240v, 60hz, according to iec60990-1 fig.13] power factor 0.95typ. efficiency % 200v 87typ. 88typ. 90typ. output characteristics output voltage edc v 24 36 48 voltage variable range edc v 16.8 to 31.2 (rv operating: 0 to 31.2) 25.2 to 55.0 (rv operating: 0 to 41.4) 33.6 to 55.0 (rv operating: 0 to 55.2) maximum output current a 50 42 32 minimum output current a 0 0 0 overvoltage threshold v 32 to 36.4 56 to 60 56 to 60 overcurrent threshold a 52.5 to 57.5 44.1 to 48.3 33.6 to 36.8 voltage stability source effect % 0.2max.(0.1typ.)[within the input voltage range] total effect1.6max.(0.8typ.) load effect % 0.4max.(0.2typ.)[0 to 100% load] temperature effect % 1.0max.(0.5typ.)[ambient temperature: ?10 to +65c] drift(time effect) % 0.5max.(0.2typ.)[25c, input and output ratings, after input voltage on for 30min to 8h] recovery % 4max.[50 to 100% sudden load change, tr, tf 50s] ripple ep-p mv 200max. 300max. 300max. ripple noise ep-p mv 300max. 400max. 400max. start up time ms 600max.(400typ.) 600max.(400typ.) 600max.(400typ.) hold up time ms 14min.(20typ.) 17min.(24typ.) 12min.(16typ.) maximum load capacitor f 100000 100000 100000 auxiliary functions indicator display led(green) indicates when voltage output is on. overvoltage protection voltage shut-down type, recover upon reset or rc reset. output low voltage detection no overcurrent protection rectangular type, automatic recovery (the output voltage will be cut off after 30 seconds. recover upon reset). overheat protection voltage shut-down type, recover upon reset. remote on-off ? 2 ye s remote sensing ? 3 ye s parallel operation possible series operation possible current balance yes synchronous operation impossible output voltage external variable function ? 4 ye s master slave operation yes alarm signal yes(power failure signal) standards safety standards ul60950, csa c22.2 no.60950(c-ul), en60950(tv) approved, electrical appliance and material safety law ("denan") (compliant with creepage surface and air clearance in attachment 8) meet. noise terminal voltage fcc-class a, vcci-class a, en55011-a, en55022-a meet. immunity en61000-4-2, 3, 4, 5, 6, 8, 11, en61000-6-2 meet. radiation field intensity fcc-class a, vcci-class a, en55011-a, en55022-a meet. constructions external dimensions mm 92 120 237[h w l] weight kg 3.0max. mounting method can be attached to 3 sides case material frame and cover: iron, circuit board: cem-3
(3/8) 002-02 / 20060413 / ea111_RKY.fm  all specifications are subject to change without notice. RKY1500w type shapes and dimensions  do not insert m4 tap installation screws more than 6mm into the power supply. ( 13 ) 16 ( 6.4) 7.62 ( 8.6 ) 10 237 120 up up 100 0.5 ( 92 ) 45 100 0.5 ( 10 ) 10 air flow ( 46 ) 46 ( 60 ) 60 60 0.5 ( 16 ) 16 160 0.5 20 25max. ( 57 ) 92 ( 35.4 )( 2.3 ) ( 43 ) ( 9 ) ( 7 ) ( 55 ) ( 12.5 ) ( 12 ) ( 17 ) ( 21 ) ( 12 ) ( 71.7 ) ( 5.7 ) ( 11.1 ) ( 15.5 ) ( 12.8 ) ( 13 ) ( 22 ) + - +s -s ref rv cb +pf -pf +rc -rc l3 l2 l1 .adj v on 8-m4 taps ( both side ) 4-m4 taps m4 8l m3 5.8l m5 12l [detail drawing of terminal block] dimensions in mm 1mm : without specified dimensions
(4/8) 002-02 / 20060413 / ea111_RKY.fm  all specifications are subject to change without notice. characteristics, functions, and applications block diagram common specifications output power-ambient temperature(deratings) temperature and humidity temperature range operating(c) ?10 to +65 operating available(c) ?20 to ?10 storage(c) ?30 to +75 humidity range operating(%)rh 10 to 95[maximum wet-bulb temperature: 35c, without dewing] storage(%)rh vibration and shock vibration 5 to 10hz all amplitude 10mm[3 directions, each 1h, sweep time 10min, non-operation] 10 to 200hz acceleration 19.6m/s 2 (2g)[3 directions, each 1h, sweep time 10min, non-operation] shock acceleration 294m/s 2 (30g)[3 directions, each 3 times, non-operation] pulse duration 115ms withstand voltage and insulation resistance withstand voltage input terminal to ground(g) eac: 2.0kv, 1min[normal temperature, normal humidity, cutout current 20ma] input terminal to output terminal eac: 3.0kv, 1min[normal temperature, normal humidity, cutout current 20ma] output terminal to ground(g) eac: 500v, 1min[normal temperature, normal humidity, cutout current 100ma] insulation resistance input terminal to ground(g) edc: 500v, 100m ? min. [normal temperature, normal humidity] input terminal to output terminal output terminal to ground(g) +s ?s l 1 l 2 l 3 + ? rv cb +rc ? rc dc output output rectifying and smoothing circuit input filter circuit input rectifier circuit surge current limiting circuit power switching circuit overcurrent detection circuit drive circuit control circuit rc control circuit boost-up circuit pfc control circuit fan alarm detection circuit overvoltage detection circuit ? p/f +p/f ref overheat detection circuit ac input 20 40 60 80 70 100 ?20 ?10 0 10 20 30 40 50 6065 71 ambient temperature(?c) output power(%) available operating range (outside of warranty)
(5/8) 002-02 / 20060413 / ea111_RKY.fm  all specifications are subject to change without notice. characteristics, functions, and applications terminal designations and functions installations terminal no. designations and functions 1 ac input terminals(l 1 , l 2 , l 3 ) connect to ac. 200 to 240v three-phase input line. 2 frame ground terminal(g) connect to earth ground. this is connected to the case. 3 dc output terminals(+, ?) connect to load. 4 remote sensing terminals when a problem occurs based on line drop from the power supply to the load, it is possible to compensate for this using remote sensing. for information about connections, please refer to the section on the remote sensing function. 5 output voltage reference terminal (ref) this terminal is for a reference voltage for controlling an output voltage and used for a master-slave operation or when using an output voltage adjustment function. normally it is shorted with a metal bar to an rv terminal. 6 output voltage adjustment terminal(rv) this terminal is used for controlling output voltage from outside. 7 current balance terminal(cb) this terminal is used when several power supplies are connected in parallel to connect the respective cb and ?s terminals in parallel. 8 power failure terminal (pf) these terminals output an open mode signal if an output voltage drops to 60 % or lower of a set voltage. they also output the signal if an output voltage is shut down due to an operation of an error detecting circuit for over output voltage protection, fan alarm overheat pro- tection, or overcurrent protection. 9 remote on-off terminals(+rc, ?rc) output is turned on-off by disconnecting-connecting the rc terminals (output on when open). rc terminals are floating. normally, rc terminals are shorted with a metal bar. 10 output voltage adjustment trim(v. adj ) adjusts output voltage. 11 operation indicator led(green) this green led becomes indicated when voltage is output. 1 2 +s -s ref rv cb +pf -pf +rc -rc l3 l2 l1 .adj v on 987654 3 10 11 (3) (2) input terminal (1) standard installation distance the fan surface at least 50 mm away from other components. and install so as to provide heat- outside air exchange. make sure not to obstruct the vent on the front panel. power supply vent hole vent hole 50mm min. fan airflow fan back front
(6/8) 002-02 / 20060413 / ea111_RKY.fm  all specifications are subject to change without notice. characteristics, functions, and applications output voltage external variable function (rv) the output voltage setting can be adjusted by attaching an exter- nal trimmer or an external voltage to the rv terminal. when using this function, use a twisted wire or a shielded wire (shield wire for ?s) for the wiring from the ref, rv, and ?s termi- nals (a recommended length is 2m max.). care must be taken to make sure that the wires are not disconnected or miswired. how to use the function  remove a short plate between the ref and rv terminals.  for adjusting output voltage with external trimmer rotate v. adj full clockwise and connect the external trimmer (5k ? ) to the ref, rv, and ?s terminals as shown in the diagram (a) below.  for adjusting output voltage with external voltage as shown in the diagram (b) in the right side, connect the exter- nal variable power supply at the + end to the rv terminal and at ? end to the ?s terminal. current balance (cb terminal) this terminal has a monitoring function to control and equalize the output current of power supplies connected in parallel by mutually connecting the respective cb terminals and the ?s terminals of each power supply. voltage almost proportional to the output cur- rent can be obtained between the cb and ?s terminals. (1)conditions for current balance the variation in output voltage between the respective power supplies cannot exceed 2% (highest voltage?lowest voltage) rated voltage=2% max. the output current is 20 to 90% of the total output rated current. (2) uniform performance (for two power supplies) the variation in output current between the respective power supplies does not exceed 10% (highest current?lowest current) (rated voltage the number of power supplies in parallel)=10% max. (3) cb terminal connection diagram equalize the impedance of the load wires coming from each power supply. use a twisted wire or a shielded wire for the wiring from cb and ?s (shield wire for ?s). the maximum four power supplies are connected in parallel. remote on-off power supply output voltage can be turned on/off externally at the remote on-off terminals (+rc, ?rc) by activating one of the fol- lowing signals: output voltage is turned off when the level is high between the +rc and ?rc terminals (open or external voltage application of 2.4 to 24v: incoming current 1.0ma max.). output voltage is turned on when the level is low between the +rc and ?rc terminals (short or terminal voltage of 0 to 0.4v: outgoing current 1.6ma max.). rc terminals are insulated from ac input terminals and the dc output terminals. insulation between the rc terminals and the output conforms to the common specifications (output to case). withstand voltage between ac input terminals and rc terminals conforms to the common specifications (input to case). power failure signal this function delivers a signal when an output voltage drops to 60% or lower of a set voltage (less than 5v for 36v). if the power supply protection function operates, however, an out- put is shut down and a power failure signal is delivered. voltage model (v) rv voltage (v) output voltage variable range (%) 24 0 to 6.5 0 to 130 36 0 to 5.75 0 to 115 48 0 to 5.75 0 to 115 ? ref rv (a) (b) + +s ?s ? ref rv + +s ?s ? + external trimmer load load external variable power supply + +s ? cb ?s rv ref + +s ? cb ?s rv ref load +rc ?rc 1.6ma max on off on in relay-shorted state on off in relay-opened state off (relay circuit) (semiconductor circuit)
(7/8) 002-02 / 20060413 / ea111_RKY.fm  all specifications are subject to change without notice. characteristics, functions, and applications output format sink current: 50ma max. collector emitter voltage: 40v max. p/f terminals are insulated from ac input terminals and the dc output terminals. insulation between the p/f terminals and the output conforms to an insulation resistance for an output to the ground of the common specifications. insulation between ac input terminals and p/f ter- minals conforms to an insulation resistance for an input terminal to an output terminal of the common specifications. p/f signal  high-impedance at error detection  maximum collector current: 50ma (collector emitter saturation voltage: 0.4v max.)  maximum collector emitter voltage: 40v power supply protection redundant (n+1) operation connect diodes to output terminals of the power supplies before their redundant operation. equalize the impedance of the load wires coming from each power supply. use a twisted wire or a shielded wire for the wiring from cb and ?s (shield wire for ?s). the maximum four power supplies are connected in parallel. master slave function a use of the ref terminal and rv terminal enables the master slave operation. connect the ref terminal of a power supply selected as a master, the rv terminals of slave power supplies, and respective ?s terminals as shown in the diagram below. then, output voltages of all the power supplies can be simulta- neously adjusted with following v. adj of the master power supply. the maximum four power supplies are connected in parallel.  for two or more output loads use a twisted wire or a shielded wire for the wiring from rv and ?s (shield wire for ?s).  for a single output load equalize the impedance of the load wires coming from each power supply. use a twisted wire or a shielded wire for the wiring from rv and ?s (shield wire for ?s). protective function operation ov output overvoltage protection output is shut down and the fan stops upon detec- tion of an abnormal output voltage rise. the output recovers after removing the cause upon setting the remote on-off terminal to a high level and then to a low level or upon an input shutdown and a reset after 40s interval. uv output under-voltage protection output is shut down when the output voltage drops to 60% or lower of the rated output voltage (36v: approx. 5v) and the condition continues for approx. 20s on over current protection and others. the out- put recovers after removing the cause upon input shutdown and a reset after a 40s minimum interval. fan fan alarm output is shut down when the fan rotation stops. the output recovers in the same manner as for the ov in the above. in case of an abnormal fan rotation, the output can- not recover. th overheat protection output is shut down and the fan stops when the internal temperature of the power supply rises abnormally. the output recovers upon an input shutdown and a reset after 40s interval. unless the internal temperature drops, the output cannot recover. +p/f ?p/f device circuit external power supply (+vcc) 40v max. ref rv cb ? ?s + +s ref rv cb ? ?s + +s load + +s ? cb ?s rv ref + +s ? cb ?s rv ref + +s ? cb ?s rv ref slave master load load load + +s ? ref rv cb ?s + +s ? ref rv cb ?s + +s ? ref rv cb ?s slave master load
(8/8) 002-02 / 20060413 / ea111_RKY.fm  all specifications are subject to change without notice. characteristics, functions, and applications insulation and withstand voltage tests the insulation and withstand voltage tests may cause deteriora- tion. care must be taken for execution of the tests. the potential must be equal among input, output, and fg (frame ground) termi- nals. it is preferable to use testers which gently start up at the test-on and automatically discharge charging energy at the test-off. man- ual discharging after the tests should be through a resistor around 100k ? to 1m ? . (do not perform discharging at low impedance. it may cause deterioration.) in any case, take full countermeasures for electric-shock preven- tion. power supply terminal connection at insulation and withstand voltage tests short output or input terminals. connections between testers and power supply at insulation and withstand voltage tests for connections between the testers and the power supply body, couple the tester terminals at the corresponding locations listed below before executing the tests. precautions  when using this unit, make sure that the ambient temperature of the power supply is within the operating temperature range. the "ambient temperature of the power supply" refers to the temper- ature near the power supply inside the device in which the unit is installed.  install space at least 10 mm away from other components on sides.  make sure to choose input/output wiring and noise filters that can safely accommodate their respective current capacities.  if the power supply is not used for extended periods of time, we recommend that you apply input voltage for about one hour every two years to maintain the capacitor?s performance.  when power supplies are used serially, the rated current will be limited by the power supply with the lowest rated current. also make sure to connect a reverse voltage protection diode (with- stand voltage: twice that of the combined output voltage. for- ward current: twice that of the output current. forward voltage drop: as small as possible) to prevent damage to the interior components caused by reverse voltage.  the materials used in these products are free of designated bro- mine flameproof materials (pbdpes and pbbs).  specific ods has not been used in the production of these prod- ucts. test conditions withstand voltage tester insulation tester + terminal ?terminal + terminal ?terminal input-to-output withstand voltage 13?? input-to-fg withstand voltage 12?? output-to-fg withstand voltage 32?? input-to-fg insulation ??1 2 input-to-output insulation ??1 3 output-to-fg insulation ??3 2 +s -s ref rv cb +pf -pf +rc -rc l3 l2 l1 .adj v on 1 in put terminal 2 fg 3 output terminal