gamewell-fci 12 clintonville road, northford, ct 06472-1610 us a ? tel: (203) 484-7161 ? fax: (203) 484-7118 specifications are for information only, are not intended for in stallation purposes, and are subj ect to change wi thout notice. no responsibility is assumed by gamewell-fci for their use. ?2008 by honeywell international inc. all rights reserved. www.gamewell-fci.com 9020-0616 rev. b2 page 1 of 2 ms-7af, ms-7 and MS-7S non-coded, manual fire alarm stations an iso 9001-2000 company approved fm 3023594 signaling 07150-0694:261 s2465 mea approved 67-02-e vol.viii description the gamewell-fci ms-7 style manual fire alarm stations are available in a wide variet y of configurations. the sta- tions comply with the americans with disabilities act (ada) 5-lb. maximum pull force requ irement. operating instruc- tions and braille text are engraved in the handle. all sta- tions have a key lock/reset which is keyed alike with gamewell-fci fire alarm control panels and other manual fire alarm stations. ms-7af velociti addressable station the ms-7af velociti ? series addressable station is a dou- ble action station designed for installation in the signaling line circuit of gamewell-fci analog addressable control panels. activation of the station causes its assigned address to register at the c ontrol panel. the door contains an led which flashes green in normal condition and lights steady red when the station has been activated.* the sta- tion features screw terminals. ms-7asf velociti addressable station the ms-7asf velociti ? series addressable station is a single action station designed for installation in the signal- ing line circuit of gamewell-fci analog addressable con- trol panels. activation of the station causes its assigned address to register at the c ontrol panel. the door contains an led which flashes green in normal condition and lights steady red when the station has been activated.* the sta- tion features screw terminals. the velociti ? series stations use a communication proto- col that substantially increas es the speed of communica- tion between the sensors and certain gamewell-fci analog addressable fire alarm controls. these devices operate in a grouped fashion. if one of the devices in the group has a status change, the panel?s microprocessor stops the group poll and focuses on the single device. the net effect is response speed up to five times greater than earlier designs. ms-7 double action station the ms-7 double action station is used with conventional- fire alarm control panels. it features a set of single pole contacts and screw terminals for connection to an initiating circuit. velociti ? is a registered trademark of honeywell international inc. ul ? is a registered trademark of underwriter?s laboratories inc. lexan ? is a registered trademark of ge plastics, a subsidiary of general electric company. features ? addressable stations compat ible with all gamewell-fci analog addressable fire alarm controls ? conventional stations suitable for use with any ul ? listed control panel ? both single and double action stations available ? tumbler lock for test and reset keyed alike with gamewell-fci controls ? surface or semi-flush mounting ? shock and vibration resistant ? stations (ms-7lob) listed for outdoor applications ? complies with ada pull force requirements only the red led is operativ e in panels that do not operate in velociti mode. ms-7
gamewell-fci 12 clintonville road, northford, ct 06472-1610 us a ? tel: (203) 484-7161 ? fax: (203) 484-7118 9020-0616 rev. b2 page 2 of 2 www.gamewell-fci.com MS-7S single action station the MS-7S single action station is used with conventional fire alarm control panels. it features a set of single pole contacts and wire leads for connection to an initiating cir- cuit. MS-7Sp double action station the MS-7Sp is a double action station similar to the ms-7 station, with the additional feature of both english and spanish instructions molded into the unit. ms-7lob double action station (listed for outdoor applications) the ms-7lob station must be mounted on a model sb-i/o backbox. in retrofit applications, the station is ul listed for use with the wp-10 backbox. it is intended for use with conventional control panels and has a set of single pole contacts and screw terminals. mounting the ms-7 interior stations may be surface mounted (use backbox sb-i/0) or semi-flush mounted on a standard dou- ble-gang, or 4-inch (10.2 cm) square electrical box. an optional trim ring (bg-tr) may also be used for semi-flush mounting. nyc-plate the nyc-plate provides the backplate for the manual pull station. (see figure 1). figure 1 nyc-plate specifications material: lexan ? contact ratings: 0.25 amps. @ 30 vac/vdc (resistive) dimensions: 5 5/8? h x 4 1/4? w x 1 1/4? d (14 x 10.1 x 3.2 cm) operating temperature (ms-7af): 32 to 120 f (0 to 49 c) relative humidity (ms-7af): 10 to 93% (non-condensing) alarm current: .0030 amp. 0.007 for led supervisory current (ms-7af): .00030 amps. ordering information model description ms-7 double action station. ms-7af** velociti addressable double action station. ms-7asf velociti addressable single action station MS-7S single action station, wire leads. MS-7Sp double action station, english and spanish instructions. ms-7lob double action station, outdoor use. (must use sb-i/o - indoor/ outdoor use backbox). sb-i/o indoor/outdoor use backback- box. sb-10 surface backbox. bg-tr. trim ring for semi-flush mount nyc-plate nyc backplate for manual pull station **for use with gamewell-fci analog addressable control panels only.
|