50W Triple Output Switching Power Supply Features : Universal AC input / Full range R T- 5 0 series Protections:Short circuit/Over load/Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test All using 105 long life electrolytic capacitors Withstand 300VAC surge input for 5 second High operating temperature up to 70 Withstand 5G vibration test High efficiency, long life and high reliability 3 years warranty SPECIFICATION MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE Note.4 Note.5 RT-50A CH1 5V 4A 0.5 ~ 5A 46.5W CH1: 4.75 ~ 5.5V 2.0% 6.0% 0.5% 1.0% 1.5% 3.0% CH2 12V 2A CH3 -5V 0.5A RT-50B CH1 5V 4A 0.5 ~ 5A 50W CH1: 4.75 ~ 5.5V 2.0% 6.0% 0.5% 1.0% 1.5% 3.0% CH2 12V 2A CH3 -12V 0.5A RT-50C CH1 5V 4A 0 ~ 5A 50W CH1: 4.75 ~ 5.5V 2.0% +8,-4% 0.5% 1.0% 1.5% 3.0% CH2 15V 1.5A 0.2 ~ 2A CH3 -15V 0.5A 0.1 ~ 1A RT-50D CH1 5V 3A 0.5 ~ 5A 51W CH1: 4.75 ~ 5.5V 2.0% + 8,-4% 0.5% 1.0% 2.0% 3.0% CH2 24V 1A CH3 12V 1A 0.2 ~ 2.5A 0.1 ~ 1A 0.2 ~ 2.5A 0.1 ~ 1A 0.2 ~ 1.5A 0.1 ~ 1A RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 100mVp-p 80mVp-p 120mVp-p 120mVp-p 80mVp-p 120mVp-p 120mVp-p 80mVp-p 150mVp-p 120mVp-p 2.0% 0.5% 1.0% 2.0% 0.5% 1.0% 2.0% 0.5% 1.0% 6.0% 2.0% 4.0% 500ms, 20ms/230VAC 60ms/230VAC 88 ~ 264VAC 47 ~ 63Hz 77% 1200ms, 30ms/115VAC at full load 10ms/115VAC at full load 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 77% 78% 80% 1.3A/115VAC 0.8A/230VAC COLD START 36A/230VAC <2mA / 240VAC 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMC (Note 6) HARMONIC CURRENT EMS IMMUNITY MTBF Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A 169.2Khrs min. MIL-HDBK-217F (25 99*97*36mm (L*W*H) 0.41Kg; 45pcs/19.5Kg/0.9CUFT ) OTHERS DIMENSION PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:RT-50-SPEC 2006-04-12 50W Triple Output Switching Power Supply Mechanical Specification R T- 5 0 Case No. 905B series Unit:mm 8.25 2 3 4 5 M 51.5 5.5 36 1 6 7 8 20.5 55 7 2- 3 3.5 4.5 89 99 6.5 87 7 17.5 3.5 18 2-M 3 74 3.5 28 36 Terminal Pin. No Assignment Pin No. 1 2 3 Assignment AC/L AC/N FG Pin No. 4 5 6 Assignment NC DC OUTPUT V3 DC OUTPUT +V2 Pin No. 7 8 Assignment DC OUTPUT COM DC OUTPUT +V1 Output Derating Output Derating VS Input Voltage Ta=25 100 100 90 80 80 60 70 LOAD (%) LOAD (%) 40 60 50 40 20 -25 -25 0 0 10 20 30 40 50 60 70 (VERTICAL) 88 95 100 115 120 140 160 55.5 180 200 97 220 3.5 240 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (VAC) 60Hz File Name:RT-50-SPEC 2006-04-12 |
Price & Availability of RT-50 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |