Part Number Hot Search : 
A1316 GL8T030 OP177G GT30J322 32180 9S08QD4 KSC2881 25F20
Product Description
Full Text Search
 

To Download NJU3754 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 NJU3754
PRELIMINARY
11-BIT PARALLEL TO SERIAL CONVERTER
GENERAL DESCRIPTION
The NJU3754 is an 11-bit parallel to serial converter especially applying to MCU input port expander. It can operate from 2.7V to 5.5V. The NJU3754 requires only 3-port of MCU for data transmission and realizes the effective input port assignment. The status of the input ports is output through a latch circuit, a shift register and a 3-state buffer as the serial data synchronizing with the serial clock. The hysteresis input circuit of the serial clock terminal realizes 5MHz and more operation. Furthermore, pull-up resistors on chip of P0 to P10 terminals reduce external components for key-scan circuit, etc.
PACKAGE OUTLINE
NJU3754V
FEATURES
11-Bit Parallel In Serial Out 3-line Serial Interface Output Hysteresis Input 0.5V typ at 5V Maximum Operating Frequency 5MHz and more Operating Voltage 2.7 to 5.5V C-MOS Technology Package Outline SSOP16
PIN CONFIGURATION
P0 P1 P2 P3 P4 P5 P6 VSS 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 VDD CE CLK SO P10 P9 P8 P7
BLOCK DIAGRAM
VSS P0 P1
Shift Register Latch Circuit
VDD SO
P2
P9 P10
Control Circuit
CE CLK
Ver.2004-03-15
-1-
NJU3754
TERMINAL DESCRIPTION
No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 SYMBOL P0 P1 P2 P3 P4 P5 P6 VSS P7 P8 P9 P10 SO CLK CE VDD I/O I I I I I I I I I I I O I I FUNCTION
Parallel Data Input Terminals (with pull-up resistors)
Ground Parallel Data Input Terminals (with pull-up resistors) Serial Data Output Terminal Serial Clock Input Terminal Chip Enable Input Terminal Power Supply Terminal (2.7 to 5.5V)
FUNCTIONAL DESCRIPTION
At the falling edge of CE terminal, the status of P0 to P10 terminal is latched and transferred to the shift register. At the mean time, the P0 data is output from SO terminal. While CE terminal is "L", the data from P1 to P10 in the shift register are synchronized with the falling edge of CLK terminal and output from SO terminal. When CE terminal is "H", SO terminal is high impedance.
Note 1) If the 11th falling edge and later are input to CLK terminal while CE is "L", the 12th and the following data are invalid. CE CLK SO P0~P10
Valid P0 P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 Invalid
-2-
Ver.2004-03-15
NJU3754 NJU3555
ABSOLUTE MAXIMUM RATINGS
(Ta=25C) PARAMETER Supply Voltage Range Input Voltage Range Power Dissipation Operating Temperature Range Storage Temperature Range SYMBOL VDD VI PD Topr Tstg RATINGS -0.3 ~ +7.0 VSS-0.3 ~ VDD+0.3 300 (SSOP) -40 ~ +85 -65 ~+150 UNIT V V mW C C
Note 2) All voltage are relative to VSS=0V reference. Note 3) Do not exceed the absolute maximum ratings, otherwise the stress may cause a permanent damage to the IC. It is also Note 4)
recommended that the IC is used in the range specified in the DC electrical characteristics, or the electrical stress may cause malfunctions and impact on the reliability. To stabilize the IC operation, place decoupling capacitor between VDD-VSS.
DC ELECTRICAL CHARACTERISTICS
PARAMETER Operating Voltage Operating Current SYMBOL VDD IDD VIH VIL IIH IIL1 IIL2 VOH VOL ITSL VDD=5V, VI=5V P0~P10, CLK, CE Terminals VDD=5V, VI=0V CLK, CE Terminals VDD=5V, VI=0V P0~P10 Terminals IOH=-0.4mA IOL=+3.2mA SO Terminal CE=H SO Terminal VDD=5.5V P0~P10=Open CE=H, CLK=L SO=No load P0~P10, CLK, CE Terminals (VDD=2.7~5.5V, VSS=0V, Ta=25C, unless otherwise noted) CONDITION MIN TYP MAX UNIT 2.7 0.7VDD VSS -1 -100 VDD-0.4 VSS -2 -40 5.5 10 VDD 0.3VDD 1 -15 VDD 0.4 2 V A V V A A A V V A
Input Voltage High-level Input Current Low-level Input Current 1 Low-level Input Current 2 Output Voltage 3-State Leakage Current
Ver.2004-03-15
-3-
NJU3754
SWITCHING CHARACTERISTICS
PARAMETER CLK Cycle Time CLK Pulse Width (H) CLK Pulse Width (L) CE Pulse Width (H) CE Set-up Time before CLK Falling CE Hold Time after CLK Falling Parallel Data Set-up Time Parallel Data Hold Time SO Delay Time after CE Falling SO Delay Time after CLK Falling SO Hold Time after CE Rising Rise Time Fall Time SYMBOL tCYC tWCH tWCL tWEH tSS tHS tSPL tHPL tDSL tDSS tDSZ tR tF (VDD=2.7~5.5V, VSS=0V, Ta=25C, unless otherwise noted) CONDITION MIN TYP MAX UNIT CLK CLK CLK CE CE - CLK CLK - CE P0~P10 - CE CE - P0~P10 CE - SO CLK - SO CE - SO
(Note 6) (Note 6) (Note 6)
200 90 90 100 100 100 50 50 -
-
-
ns ns ns ns ns ns
50 50 20 20 20
ns ns ns ns ns ns ns
CLK Terminal CLK, CE Terminals
Note 5) A 15k pull-up or pull-down resistor and a 50pF capacitor on the SO terminal. Note 6) All timings are based on 30% and 70% voltage level of VDD.
-4-
Ver.2004-03-15
NJU3754 NJU3555
TIMING CHARTS
CE tSPL P0~P10 tHS CLK tF tWCL tR tWCH tHPL
VALID tSS tCYC
tDSL SO
tDSS
tWEH CE tDSZ SO
Ver.2004-03-15
-5-
NJU3754
APPLICATION CIRCUIT
P0 CE
P1
P2
P3
P4
P5
P6 P7
MCU
CLK SO
NJU3754
P8 P9 P10
[CAUTION] The specifications on this databook are only given for information , without any guarantee as regards either mistakes or omissions. The application circuits in this databook are described only to show representative usages of the product and not intended for the guarantee or permission of any right including the industrial rights.
-6-
Ver.2004-03-15


▲Up To Search▲   

 
Price & Availability of NJU3754

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X